Sign In | Join Free | My himfr.com
Home > Environmental Test Chamber >

Curve Tester Circuit Board Detection Asa Tester 4 Gear Frequency Alternating Speed

    Buy cheap Curve Tester Circuit Board Detection Asa Tester 4 Gear Frequency Alternating Speed from wholesalers
     
    Buy cheap Curve Tester Circuit Board Detection Asa Tester 4 Gear Frequency Alternating Speed from wholesalers
    • Buy cheap Curve Tester Circuit Board Detection Asa Tester 4 Gear Frequency Alternating Speed from wholesalers
    • Buy cheap Curve Tester Circuit Board Detection Asa Tester 4 Gear Frequency Alternating Speed from wholesalers
    • Buy cheap Curve Tester Circuit Board Detection Asa Tester 4 Gear Frequency Alternating Speed from wholesalers
    • Buy cheap Curve Tester Circuit Board Detection Asa Tester 4 Gear Frequency Alternating Speed from wholesalers

    Curve Tester Circuit Board Detection Asa Tester 4 Gear Frequency Alternating Speed

    Ask Lasest Price
    Brand Name : YU YANG
    Model Number : YY0014
    Certification : CE
    Price : Negotiable
    Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
    Supply Ability : 5 Pcs Per Month
    Delivery Time : 7-30 Days
    • Product Details
    • Company Profile

    Curve Tester Circuit Board Detection Asa Tester 4 Gear Frequency Alternating Speed

    Curve Tester Circuit Board Detection Asa Tester 4 Gear Frequency Alternating Speed


    Description:

    Our UV Aging Test Lamp is designed to perform comprehensive aging tests on non - metallic materials for various applications. It is perfect for materials used in the agriculture, horticulture, and gardening industries. Made with weather - resistant materials, this lamp can generate UV light to simulate real - world sunlight exposure. It can cause the tested materials to show signs of degradation, including color fading, cracking, and loss of strength, allowing for better product quality control.


    Design criteria:


    (1) ASTM D4587: Standard Practice for Fluorescent UV-Condensation Exposures of Paint and Related Coatings

    (2) ASTM D4799: Standard Practice for Accelerated Weathering Test Conditions and Procedures for Bituminous Materials (Fluorescent UV, Water Spray, and Condensation Method)

    (3) ISO 4892-1: Plastics - Methods of Exposure to Laboratory Light Sources - Part 1: General guidance

    (4) ISO 4892-3: Plastics - Methods of Exposure to Laboratory Light Sources - Part 3: Fluorescent UV Lamps

    (5) ASTM D4329: Standard Practice for Fluorescent UV Exposure of Plastics

    (6) AATCC TM186: Weather Resistance: UV Light and Moisture Exposure


    Control System:

    Control System 5** Utilizes a black anodized aluminum plate to link up with the temperature sensor, and a black - board temperature controller is employed to regulate the heating, ensuring a more stable temperature condition. The radiometer probe is fixed stably to prevent frequent installation and removal activities. The radiation quantity is measured by a dedicated UV irradiometer with high - precision display and measurement accuracy. The radiation intensity is capped at 50W/m². Illumination and condensation can be controlled independently or in an alternating, circular cycle.


    Standard specimen size75×290mm/24 pieces
    Power1 phase, 220V/50Hz /±10% 5KW
    blackboard temperature rangeroom temperature 30 ℃ ~ + 80 ℃
    Irradiation black panel temperature50℃~70℃
    Material:Stainless Steel
    Lifetime of lamp1600Hours
    Lamp power & length40W/Piece, 1200mm/Piece

    Curve Tester Circuit Board Detection Asa Tester 4 Gear Frequency Alternating SpeedCurve Tester Circuit Board Detection Asa Tester 4 Gear Frequency Alternating SpeedCurve Tester Circuit Board Detection Asa Tester 4 Gear Frequency Alternating Speed

    FAQ

    1. How to choose the appropriate model of the ultraviolet aging test chamber?

    To choose the appropriate model, you need to consider the type, size, and quantity of the test materials, as well as the range of environmental conditions to be simulated. At the same time, pay attention to the performance parameters of the equipment, brand reputation, and after - sales service to meet the actual test requirements.

    2. Can the light intensity of the test chamber be adjusted?

    The light intensity of most ultraviolet aging test chambers can be adjusted. By adjusting the light intensity, it is possible to simulate the differences in sunlight intensity in different regions and seasons, making the test conditions more in line with the actual application scenarios.

    3.Can the test chamber be opened during the operation of the equipment?

    It is not recommended to open the test chamber during the operation of the equipment. Since the inside of the chamber is under specific environmental conditions during operation, sudden opening will disrupt the test environment, affect the accuracy of the test results, and may also pose certain safety risks.

    can effectively evaluate the aging - resistance of these materials.
    If you are interested in any of our products or would like to discuss a custom order. Please feel free to contact us. We are looking forward to forming succesful business with new clients around the world in the near future.


    Quality Curve Tester Circuit Board Detection Asa Tester 4 Gear Frequency Alternating Speed for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: DONGGUAN YUYANG INSTRUMENT CO., LTD
    *Subject:
    *Message:
    Characters Remaining: (0/3000)